ORTHOPAEDIC INSTRUMENTS & KITS

Disposable single-use instruments and procedural kits are now available for demanding orthopaedic procedures. ECA Medical Instruments® is the pioneer and industry leader in designing and manufacturing precision single-procedure torque limiting instruments including its new Torque-Fast family of AO and ¼ inch square instruments and its Model 900 series of surgical procedure kits for orthopaedics. From off the shelf and sterile ready products to customized designs and sterile packed products, ECA solutions are the industry standard for quality and performance.

Torque-Limiting Instruments

Model Torque Range Handle
Design
Procedure/Application
1.0 - 5.0 lb./in (0.112 - 0.560 Nm) Triangular CRM, Cardiovascular, Neuro, Ortho, Trauma
1.0 - 5.0 lb./in (0.112 - 0.560 Nm) Triangular CRM, Cardiovascular, Neuro, Ortho, Trauma
5.0 - 20 lb./in. (0.550 - 2.24 Nm) Medium
Axial
CMF, Small Bone, Spine, Trauma, Implants, General Ortho
5.0 - 20.0 lb./in. (0.550 - 2.24 Nm) Palm
Handle
Implants, CMF, Small Bone, Spine, Trauma, General Ortho
20 - 40 lb./in. (2.25 - 4.51 Nm) Large Axial Handle Implants, CMF, Small Bone, Spine, Trauma, General Ortho
20 - 50 lb./in. (2.25 - 5.64 Nm) Axial Handle with 1/4" square, AO or other coupling Implants, Spine, Trauma, General Ortho
10 - 40 lb./in. (1.12 - 4.51 Nm) T-Handle Implants, Spine, Trauma, General Ortho
40 - 90 lb./in. (4.51 - 10.16 Nm) T - Handle with 1/4" square, AO or other coupling Implants, Spine, Trauma, General Ortho

Fixed Driver Instruments

Model Description Dimensions Handle
Design
Procedure/Application
Small fixed-drivers with stainless steel hex shafts 1.67"L x 0.25"D
1.05"L x 0.43"D
Axial CRM, Neuro, Cardiovascular, CMF, Trauma
Small fixed-driver with stainless steel hex shaft 1.36"L x 0.69"D Axial CRM, Neuro, Cardiovascular, CMF, Trauma
Palm fixed-driver with stainless steel hex shaft with Wick Away® technology 8.99"L x 1.5"D Medium
Palm
CRM, Neuro, Cardiovascular, CMF, Spine, Small Bone, Trauma, General Ortho
Palm Awl with stainless steel hex shaft with Wick Away® technology 5.48"L x 1.5"D Medium
Palm
CRM, Neuro, Cardiovascular, CMF, Spine, Small Bone, Trauma, General Ortho
Axial Palm fixed-driver with stainless steel hex shaft with Wick Away® technology 10.50"L x 1.25"D Medium
Axial
CRM, Neuro, Cardiovascular, CMF, Spine, Small Bone, Trauma, General Ortho
Fingertip swivel fixed- driver for precision control with Wick Away® technology 7.48"L x 0.50"D Medium
Axial
Implants, CMF, Small Bone, Spine, Trauma, General Ortho
Precision palm control and actuation with Wick Away®
technology
8.36"L x 1.0"D Crown Top Neuro, VAD, Implants, Spine, Trauma, General Ortho
Fixed polymer T-Handle and stainless steel driver 3.0"L x 3.92"D T-Handle Implants, Spine, Trauma, General Ortho

Single-Procedure, Torque-Limiting Surgical Kits

Model General Description Procedure/Application
Torque limiting instruments:
• 218 Long Tri-Lobe
• 219 Palm
• 225 Large Axial with ¼" square
• 225 T-Handle with ¼" square

Fixed-driver instruments:
• Standard FD Axial
Reconstruction, Spine and General Orthopaedic Procedures
Torque limiting instruments:
• 219 Medium Axial
• 220 T-Handle
Fixed-driver instruments:
• Standard FD Palm Awl
• Standard FD Medium Axial
ACF, Spine, Small Bone, Trauma, General Orthopaedic Procedures
Torque limiting instruments:
• 218 Long Tri-Lobe
• 219 Medium Axial

Fixed-driver instruments:
• SpeedECAp™ Standard Spin-Top FD
• Standard FD Palm Awl
• Standard FD Medium Axial
CMF, Trauma, Clavicle, Hand/Foot

Single-Procedure, Torque-Fast

Model General Description Torque Range Handle Design Max Torque Actuations
Model 218 with
AO connector and
Tri-Lobe Handle
1.0-5.0 lb./in.
(0.112-0.550 Nm)
Triangular 30
Model 219 with
AO connector and
Palm Handle
5.0-20.0 lb./in.
(0.550-2.24 Nm)
Palm 50
Model 219 with
AO connector and
Axial Handle
5.0-20.0 lb./in.
(0.550-2.24 Nm)
Axial 50
Model 225 with AO and
¼" square connector and
Axial Handle
40 lb./in. to 80 lb./in.
(4.51-9.16 Nm)
Axial 50
Model 225 with AO and
1⁄4" square connector
and T-Handle
40 lb./in. to 80 lb./in.
(4.51-9.16 Nm)
T-Handle 50